MG6 measurement and control data recorder is a powerful core component of the data acquisition system.
MG6 data recorder can provide fast communication, low power consumption, built-in USB, compact size, and high analog input precision and resolution. It uses universal (U) terminals to allow connection to almost any sensor - analog, digital or intelligent. The multifunctional data recorder can also measure the static vibration chord.
Features:
It can operate in extreme environments with a standard operating range of - 40 ° to+70 ° C and an extended operating range of - 55 ° to+85 ° C
Connect directly to your computer's USB port
U terminal can be configured as the terminal you want: analog or digital, input or output
Use spectral analysis technology to support static chord measurement
Through high resolution measurement (to 0.05 µ V, 24 bit Adc), even small changes in data values can be distinguished
Includes an onboard CPI port for hosting Campbell sensors and Distributed Modules (CDM)
Direct connection to Ethernet via 10/100 Ethernet RJ-45 or Ethernet via USB (virtual Ethernet)
Includes a microSD card driver to meet expanded memory requirements
Simple serial sensor integration and measurement via SDI-12, RS-232 and/or RS-485
Supports full PakBus ® network
Including embedded web pages, which can be directly connected through a web browser
Main performance parameters:
Operating temperature range: - 40 ° to+70 ° C (standard), - 55 ° to+85 ° C (extended) (non condensing environment)
Case material: high impact resistant polycarbonate and UV resistant TPE, recycling code 7
Universal Inputs: 12 individually configured inputs for analog or digital functions
Pulse counter: 16 (C1 to C4 and U1 to U12)
Communication port: Ethernet; USB Micro B; CS I/O; RS-232; CPI; RS-485; SDI-12
Data storage port: microSD
Switch 12V: 2 terminals
Digital I/O: 16 terminals (C1 to C4, U1 to U12) can be configured for digital input and output. Terminals can be configured in pairs to achieve 5 V or 3.3 V logic for some functions.
Input range: ± 5 V
Analog voltage accuracy: (accuracy specification does not include sensor or measurement noise)
± (0.04% of measured value+offset) at 0 ° to 40 ° C- ± (0.06% of measured value+offset) at 40 ° to+70 ° C- ± (0.08% of measured value+offset) from 55 ° to+85 ° C (extended temperature range)
ADC: 24 bit
Power requirements: Charger input (CHG) 16 to 32 Vdc (current limit 12 Vdc to 1.2 A, maximum 20 ° C)
10 to 18 Vdc of battery input (BAT) (max. 2.5 A at current limit of 12 Vdc to 20 ° C)
Real time clock accuracy: ± 3 minutes per year (optional GPS correction to ± 10 µ s)
Internet protocols: Ethernet, PPP, CS I/O IP, RNDIS, ICMP/Ping, Automatic IP (APIPA), IPv4, IPv6, UDP, TCP, TLS (v1.2), DNS, DHCP, SLAAC, SNMPv3, NTP, Telnet, HTTP (S), FTP (S), SMTP/TLS, POP3/TLS
Communication protocols: CPI, PakBus, SDM, SDI-12, Modbus, TCP, DNP3, UDP, NTCIP, NMEA 0183, I2C, SPI, etc
Battery powered SRAM for CPU usage and final storage: 4 MB
Data storage: 4 MB SRAM+72 MB flash memory (up to 16 GB of storage can be expanded with removable microSD flash memory card)
Standby power consumption (average): assume 12 Vdc on BAT terminal; If CHG terminal is used, increase 2 mA<1 mA
Operating power consumption (average): assume 12 Vdc on BAT terminal; If CHG terminal is used, increase 2 mA 3, mA (1 Hz scan), 67 mA (20 Hz scan)
Static chord measurement: support
Dimensions: 21.0 x 10.2 x 5.6 cm (8.3 x 4.0 x 2.2 in)
Weight: 0.42 to 0.52 kg (0.92 to 1.15 lb), depending on the communication option selected