data collector

MG6 data collector

MG6 measurement and control data recorder is a powerful core component of the data acquisition system.MG6 data recorder can provide fast communication, low power consumption, built-in USB, compact siz

MG6 measurement and control data recorder is a powerful core component of the data acquisition system.

MG6 data recorder can provide fast communication, low power consumption, built-in USB, compact size, and high analog input precision and resolution. It uses universal (U) terminals to allow connection to almost any sensor - analog, digital or intelligent. The multifunctional data recorder can also measure the static vibration chord.

Features:

It can operate in extreme environments with a standard operating range of - 40 ° to+70 ° C and an extended operating range of - 55 ° to+85 ° C

Connect directly to your computer's USB port

U terminal can be configured as the terminal you want: analog or digital, input or output

Use spectral analysis technology to support static chord measurement

Through high resolution measurement (to 0.05 µ V, 24 bit Adc), even small changes in data values can be distinguished

Includes an onboard CPI port for hosting Campbell sensors and Distributed Modules (CDM)

Direct connection to Ethernet via 10/100 Ethernet RJ-45 or Ethernet via USB (virtual Ethernet)

Includes a microSD card driver to meet expanded memory requirements

Simple serial sensor integration and measurement via SDI-12, RS-232 and/or RS-485

Supports full PakBus ® network

Including embedded web pages, which can be directly connected through a web browser


Main performance parameters:

Operating temperature range: - 40 ° to+70 ° C (standard), - 55 ° to+85 ° C (extended) (non condensing environment)

Case material: high impact resistant polycarbonate and UV resistant TPE, recycling code 7

Universal Inputs: 12 individually configured inputs for analog or digital functions

Pulse counter: 16 (C1 to C4 and U1 to U12)

Communication port: Ethernet; USB Micro B; CS I/O; RS-232; CPI; RS-485; SDI-12

Data storage port: microSD

Switch 12V: 2 terminals

Digital I/O: 16 terminals (C1 to C4, U1 to U12) can be configured for digital input and output. Terminals can be configured in pairs to achieve 5 V or 3.3 V logic for some functions.

Input range: ± 5 V

Analog voltage accuracy: (accuracy specification does not include sensor or measurement noise)

± (0.04% of measured value+offset) at 0 ° to 40 ° C- ± (0.06% of measured value+offset) at 40 ° to+70 ° C- ± (0.08% of measured value+offset) from 55 ° to+85 ° C (extended temperature range)

ADC: 24 bit

Power requirements: Charger input (CHG) 16 to 32 Vdc (current limit 12 Vdc to 1.2 A, maximum 20 ° C)

10 to 18 Vdc of battery input (BAT) (max. 2.5 A at current limit of 12 Vdc to 20 ° C)

Real time clock accuracy: ± 3 minutes per year (optional GPS correction to ± 10 µ s)

Internet protocols: Ethernet, PPP, CS I/O IP, RNDIS, ICMP/Ping, Automatic IP (APIPA), IPv4, IPv6, UDP, TCP, TLS (v1.2), DNS, DHCP, SLAAC, SNMPv3, NTP, Telnet, HTTP (S), FTP (S), SMTP/TLS, POP3/TLS

Communication protocols: CPI, PakBus, SDM, SDI-12, Modbus, TCP, DNP3, UDP, NTCIP, NMEA 0183, I2C, SPI, etc

Battery powered SRAM for CPU usage and final storage: 4 MB

Data storage: 4 MB SRAM+72 MB flash memory (up to 16 GB of storage can be expanded with removable microSD flash memory card)

Standby power consumption (average): assume 12 Vdc on BAT terminal; If CHG terminal is used, increase 2 mA<1 mA

Operating power consumption (average): assume 12 Vdc on BAT terminal; If CHG terminal is used, increase 2 mA 3, mA (1 Hz scan), 67 mA (20 Hz scan)

Static chord measurement: support

Dimensions: 21.0 x 10.2 x 5.6 cm (8.3 x 4.0 x 2.2 in)

Weight: 0.42 to 0.52 kg (0.92 to 1.15 lb), depending on the communication option selected